Newport Medical Instruments, Inc.
March 18, 2008 — health1620 Sunflower Ave.
92626 Costa Mesa, CA
USA
Phone: +1-714-427-5811
Fax: +1-714427-0489
http://www.ventilators.com
info@ventilators.com
Company Contacts
Department/ Name Address
Director of Marketing – Karen Faber Tel: 800.451.3111 ext. 312, 714.427.5811, Fax: 714.427.0489
kfaber@nmitkb.com
Company Figures
Number of employees 100-499
Year of foundation 1981
Area of business Electronical Equipment / Medical Technology
Company Profile
Leading the way in patient ventilation
At Newport Medical Instruments, our foremost priority is to properly serve patients who require ventilator support. To this end, we are dedicated to providing high-quality, clinically beneficial and cost-effective products and services. With this dedication and continued diligence, we have grown to become the world’s largest, privately owned ventilator company.
Since 1981, Newport has been designing and manufacturing ventilators that are versatile and affordable. Our pioneering Newport E100 was the first ventilator that could be used for neonates, pediatrics and adults. Our newest generation of technologically advanced critical care ventilators provide multi-functions and leading-edge features that are both user and patient friendly.
Today, Newport ventilators are available in 116 countries and we have an extensive distribution network with over 90 worldwide locations. Our professionally trained staff of local Newport representatives provides personalized service specific to each customer’s needs and culture. Newport diligently maintains the highest standard of quality in all areas of manufacturing and design. To ensure our position as a leading provider of safe, reliable ventilators around the world, we continue to invest in research and innovative product development. We are ISO certified and our products meet all approprate agency requirements, including FDA, UL, CSA, CE, TUV, JIS and other global licenses.
ewport builds versatility into all of our products. We offer ventilators for neonatal, pediatric and adult patients that can be used in many applications, from emergency and intensive care, to subacute and home care. We continually strive to improve the care and comfort of ventilated patients. From our initial groundbreaking concept of ‘duo-flow’ for better infant ventilation, to our innovative new systems for effective breath management, Newport designs patient-focused, solution-oriented ventilation into all of our products.
We focus on improving the essential qualities of a ventilator rather than adding extraneous features. This allows us to meet the cost-effective, outcome-oriented requirements of health care facilities while still providing the quality of care that patients demand.
We pride ourselves in providing personalized and responsive customer service. We offer extensive clinical education and technical service and we maintain an around-the-clock helpline for urgent needs. Our website also provides educational support materials, up-to-date product information and easy contact access.
Our dedication to innovation, and product and service excellence has earned us a global reputation for quality and reliability. We have built a stable foundation for future growth and look forward to continually advancing ventilator technology for both our clients and their patients. For more information, contact your local Newport representative or our customer service department.
Product Information
01.04.02 Respiration equipment
Breeze E150 Ventilator
Special Features:
DuoFlow System
The Breeze separates the spontaneous flow system from the mechanical flow system. We call this ‘DuoFlow’. The DuoFlow system allows you to customize the pressure wave pattern of the mechanical breath in order to meet time constant restraints, and then tailor the spontaneous flowrate for maximum patient comfort and minimum work of breathing. Comprehensive Alarms
The alarms are simple to set using the high and low control knobs and easy to read in the back-lit digital display. Compact Size
Less than 12 inches square, the Breeze fits into small areas where space is limited. (It also fits into tight budgets!) Built-In Battery Back-Up
The E150’s emergency back up power (for up to one hour) is essential for added safety in busy hospitals.
Breeze E150 Ventilator
Special Features:
DuoFlow System
The Breeze separates the spontaneous flow system from the mechanical flow system. We call this ‘DuoFlow’. The DuoFlow system allows you to customize the pressure wave pattern of the mechanical breath in order to meet time constant restraints, and then tailor the spontaneous flowrate for maximum patient comfort and minimum work of breathing.
Comprehensive Alarms
The alarms are simple to set using the high and low control knobs and easy to read in the back-lit digital display.
Compact Size
Less than 12 inches square, the Breeze fits into small areas where space is limited. (It also fits into tight budgets!)
Built-In Battery Back-Up
The E150’s emergency back up power (for up to one hour) is essential for added safety in busy hospitals.
C230 Air Compressor
The NEWPORT C230 Air Compressor is an ideal air source for all NEWPORT ventilators, including the new e500 Wave Ventilator, when piped-in compressed air is not available or when you need a back-up air source for added protection. The custom designed trolley allows for quick mounting of Newport ventilators. Easily accessible filter and indicators make regular maintenance simple and cost effective. Large, lockable wheels provide effortless mobility and stability.
C230 Air Compressor features include: 200 L/min flow capability
large drying system for cool, condensation-free air
easy access for maintenance and servicing
humidifier mounting on either side of compressor
quick connect for central gas system
Designed and engineered utilizing proven, high quality components, the C230 Air Compressor will provide years of reliable performance for your facility.
Contact NEWPORT or your local NEWPORT representative today for a demonstration of the C230 Air Compressor.
C230 Air Compressor
The NEWPORT C230 Air Compressor is an ideal air source for all NEWPORT ventilators, including the new e500 Wave Ventilator, when piped-in compressed air is not available or when you need a back-up air source for added protection. The custom designed trolley allows for quick mounting of Newport ventilators. Easily accessible filter and indicators make regular maintenance simple and cost effective. Large, lockable wheels provide effortless mobility and stability.
C230 Air Compressor features include: 200 L/min flow capability
large drying system for cool, condensation-free air
easy access for maintenance and servicing
humidifier mounting on either side of compressor
quick connect for central gas system
Designed and engineered utilizing proven, high quality components, the C230 Air Compressor will provide years of reliable performance for your facility.
Contact NEWPORT or your local NEWPORT representative today for a demonstration of the C230 Air Compressor.
C250 Air Compressor
The Newport C250 Air Compressor provides high-flow capability and whisper quiet operation. The C250 is an ideal air source for all Newport ventilators when piped-in compressed air is not available or when you need a back-up air source for added protection.
The custom designed handle allows for quick mounting of any Newport ventilator. Easily accessible filters and indicators make regular maintenance simple and cost effective. Large, lockable wheels provide effortless mobility and stability.
C250 Air Compressor features include:
Extremely reliable, whisper quiet motor
High temperature/low pressure alarm for added safety
200 L/min flow capability
Large drying system for cool, condensation-free air
Easy access for maintenance and servicing
Internal circuit breaker protects against pump overheating
Universal humidifier mounting pole
Designed and engineered by Newport utilizing proven, high quality components, the C250 Air Compressor will provide years of reliable performance for your facility.
C250 Air Compressor
The Newport C250 Air Compressor provides high-flow capability and whisper quiet operation. The C250 is an ideal air source for all Newport ventilators when piped-in compressed air is not available or when you need a back-up air source for added protection.
The custom designed handle allows for quick mounting of any Newport ventilator. Easily accessible filters and indicators make regular maintenance simple and cost effective. Large, lockable wheels provide effortless mobility and stability.
C250 Air Compressor features include:
Extremely reliable, whisper quiet motor
High temperature/low pressure alarm for added safety
200 L/min flow capability
Large drying system for cool, condensation-free air
Easy access for maintenance and servicing
Internal circuit breaker protects against pump overheating
Universal humidifier mounting pole
Designed and engineered by Newport utilizing proven, high quality components, the C250 Air Compressor will provide years of reliable performance for your facility.
E100M Ventilator
Special Features:
DuoFlow Plus
As you wean a patient, you may gradually decrease the number of mandatory breaths and rely on the patient to take over more responsibility for ventilation with spontaneous breaths. Weaning success may be affected by how the patient tolerates the increase in work load.
Newport’s unique DuoFlow PLUS system allows you to make the patient more comfortable during spontaneous breathing by providing a higher flow at the onset of effort which drops to a lower flow as effort subsides. This can ease patient work for spontaneous breathing and also help to decrease expiratory resistance, improve mandatory breath triggering and decrease ventilator gas consumption.
Advanced Trigger Control
Throughout the patient’s course of mechanical ventilation, circuit leaks or physiologic changes may impact the effectiveness of the Trigger setting. Since an appropriate Trigger setting is essential for maintaining patient/ventilator synchrony, the bedside clinician must re-adjust Trigger regularly to keep the ventilator sensitive to patient efforts without artifact triggering.
With Newport’s introduction of Advanced Trigger Control (ATC), a simple push of a button ensures that the Trigger setting is automatically re-adjusted as patient or circuit conditions change. The ATC feature can provide improved patient/ventilator synchrony even when you cannot be at the bedside.
Interface Output
The E100M features an RS232 Output to interface with a central monitoring system and a 4:1 Inverse Ratio capability which can provide greater ventilation flexibility.
Comprehensive Monitoring
Includes Peak, Mean and Base Airway Pressure, Set Tidal Volume, I:E, Total Frequency and % Battery Charge.
E100M Ventilator
Special Features:
DuoFlow Plus
As you wean a patient, you may gradually decrease the number of mandatory breaths and rely on the patient to take over more responsibility for ventilation with spontaneous breaths. Weaning success may be affected by how the patient tolerates the increase in work load.
Newport’s unique DuoFlow PLUS system allows you to make the patient more comfortable during spontaneous breathing by providing a higher flow at the onset of effort which drops to a lower flow as effort subsides. This can ease patient work for spontaneous breathing and also help to decrease expiratory resistance, improve mandatory breath triggering and decrease ventilator gas consumption.
Advanced Trigger Control
Throughout the patient’s course of mechanical ventilation, circuit leaks or physiologic changes may impact the effectiveness of the Trigger setting. Since an appropriate Trigger setting is essential for maintaining patient/ventilator synchrony, the bedside clinician must re-adjust Trigger regularly to keep the ventilator sensitive to patient efforts without artifact triggering.
With Newport’s introduction of Advanced Trigger Control (ATC), a simple push of a button ensures that the Trigger setting is automatically re-adjusted as patient or circuit conditions change. The ATC feature can provide improved patient/ventilator synchrony even when you cannot be at the bedside.
Interface Output
The E100M features an RS232 Output to interface with a central monitoring system and a 4:1 Inverse Ratio capability which can provide greater ventilation flexibility.
Comprehensive Monitoring
Includes Peak, Mean and Base Airway Pressure, Set Tidal Volume, I:E, Total Frequency and % Battery Charge.
HT50 Ventilator
Special Features:
Volume or Pressure Control Ventilation
Invasive or Non-Invasive Ventilation
Pressure Support
Back-up Ventilation
PEEP/CPAP
Comprehensive Alarms/Monitoring
Built-in Battery, up to 10 hours
Unique Gas Delivery System Requires No External Air Compressor
Optional Built-in Heated Humidifier
Optional Air/Oxygen Mixer
HT50 Ventilator
Special Features:
Volume or Pressure Control Ventilation
Invasive or Non-Invasive Ventilation
Pressure Support
Back-up Ventilation
PEEP/CPAP
Comprehensive Alarms/Monitoring
Built-in Battery, up to 10 hours
Unique Gas Delivery System Requires No External Air Compressor
Optional Built-in Heated Humidifier
Optional Air/Oxygen Mixer
MAXO Oxygen Monitors
Our MAXO2 (OM25-series) monitors have been specifically designed to meet the needs of hospitals and home health care providers. The MAXO2 offers unmatched performance and reliability.
Simple Operation
Exceptional Stability
Extra Life Oxygen Sensor
Low Cost of Ownership
OM-25 MEL *not shown Low-Limit Alarm (to 15%)
MAXO Oxygen Monitors
Our MAXO2 (OM25-series) monitors have been specifically designed to meet the needs of hospitals and home health care providers. The MAXO2 offers unmatched performance and reliability.
Simple Operation
Exceptional Stability
Extra Life Oxygen Sensor
Low Cost of Ownership
OM-25 MEL *not shown Low-Limit Alarm (to 15%)
Sensors
The MAX-family of oxygen sensors feature exceptional stability and extra long life in a fast response sensor.
Link to further Information
Sensors
The MAX-family of oxygen sensors feature exceptional stability and extra long life in a fast response sensor.
The Next Generation…Handi
Now you can breathe a little easier with the Handi™ advantage.
3 Digit LCD Display *New Feature
Splash Resistant *New Feature
Simple, Reliable and Affordable
Maintenance Free
Pocket Size
Convenient Lanyard Included
The Next Generation…Handi
Now you can breathe a little easier with the Handi™ advantage.
3 Digit LCD Display *New Feature
Splash Resistant *New Feature
Simple, Reliable and Affordable
Maintenance Free
Pocket Size
Convenient Lanyard Included
Wave E200 Ventilator
The Wave VM200 was designed with a focus on harmony between patient and ventilator. It’s advanced features provide rapid, responsive ventilation to help speed weaning. And with one ventilator for all patient applications you can standardize your clinical training, simplify ventilator management and lower your maintenance costs.
Wave E200 Ventilator
The Wave VM200 was designed with a focus on harmony between patient and ventilator. It’s advanced features provide rapid, responsive ventilation to help speed weaning. And with one ventilator for all patient applications you can standardize your clinical training, simplify ventilator management and lower your maintenance costs.
e360 Ventilator
Special Features:
The Intelligent ControlSM System for greater patient/ventilator synchrony
The e360 Plus with the Intelligent Control SystemSM adds more efficiency to every day operation while helping you to improve patient outcomes. Patient/ventilator interaction can be optimized when these expanded features are applied:
Automatic Leak Compensation
Automatic Slope/Rise
Dual Control Adaptive Breath Management
FlexCycleTM Flexible Pressure Support Cycling Expiratory Threshold*
*This patented feature actively manages the Pressure Support/VTPS cycling-off threshold, breath by breath. Using a unique feedback controlled algorithm, FlexCycle automatically manages the flow threshold settings, so you don’t have to. A managed Expiratory Threshold setting can provide better patient/ventilator synchrony in the transition from inspiration to expiration.
Low Cost of Ownership
The Newport e360 can meet the cost containment requirements your hospital demands. We understand that purchase price is important but what a ventilator will cost you annually is critical. That’s why Newport builds low cost of ownership and economical pricing into the e360 ventilator.
e360 Graphical User Interface touchscreen puts more data at your fingertips.
Compact and concise, the GUI displays:
waveforms
loops
trends
measured and calculated data
In addition, the GUI gives the user easy access to a quick Circuit Check for pre-use tests, customized patient setup options and alarm settings. To aid in patient weaning the e360 offers a calculated Rapid Shallow Breath Index (RSBI) that can also be trended. The Event History screen displays 1000 of the latest events in a color-coded, easy to review log.
e360 Ventilator
Special Features:
The Intelligent ControlSM System for greater patient/ventilator synchrony
The e360 Plus with the Intelligent Control SystemSM adds more efficiency to every day operation while helping you to improve patient outcomes. Patient/ventilator interaction can be optimized when these expanded features are applied:
Automatic Leak Compensation
Automatic Slope/Rise
Dual Control Adaptive Breath Management
FlexCycleTM Flexible Pressure Support Cycling Expiratory Threshold*
*This patented feature actively manages the Pressure Support/VTPS cycling-off threshold, breath by breath. Using a unique feedback controlled algorithm, FlexCycle automatically manages the flow threshold settings, so you don’t have to. A managed Expiratory Threshold setting can provide better patient/ventilator synchrony in the transition from inspiration to expiration.
Low Cost of Ownership
The Newport e360 can meet the cost containment requirements your hospital demands. We understand that purchase price is important but what a ventilator will cost you annually is critical. That’s why Newport builds low cost of ownership and economical pricing into the e360 ventilator.
e360 Graphical User Interface touchscreen puts more data at your fingertips.
Compact and concise, the GUI displays:
waveforms
loops
trends
measured and calculated data
In addition, the GUI gives the user easy access to a quick Circuit Check for pre-use tests, customized patient setup options and alarm settings. To aid in patient weaning the e360 offers a calculated Rapid Shallow Breath Index (RSBI) that can also be trended. The Event History screen displays 1000 of the latest events in a color-coded, easy to review log.
e500 Ventilator
Special Features
Intelligent Control™ System
FlexCycle™ Flexible Pressure Support Cycling Threshold, Automatic Slope/Rise Adjustment, Automatic Leak Compensation, Dual Control Breath Management (VTPC/VTPS).
Suction Disconnect
Press and hold Alarm Silence for one second to enable. Suspends ventilation while delivering continuous flow after a planned disconnect.
User Set Up Functions
Leak Test, Circuit Compliance Compensation (calculate and enable breathing circuit compliance of flow/volume delivery), enable 90-second Slow Inflation, Altitude Compensation, Language Selection, Violation Message Log.
Bias Flow
Ventilator-set bias flow flushes exhaled CO2 and stabilizes temperature, humidity and baseline pressure in the patient breathing circuit.
Non-invasive Ventilation
Compatible with mask ventilation for continuous or short term use.
O2 Calibration
Automatic oxygen sensor calibration at software determined intervals.
Preset Vent Settings
Mode, Breath type and settings can be preset without affecting current ventilator operation.
e500 Ventilator
Special Features
Intelligent Control™ System
FlexCycle™ Flexible Pressure Support Cycling Threshold, Automatic Slope/Rise Adjustment, Automatic Leak Compensation, Dual Control Breath Management (VTPC/VTPS).
Suction Disconnect
Press and hold Alarm Silence for one second to enable. Suspends ventilation while delivering continuous flow after a planned disconnect.
User Set Up Functions
Leak Test, Circuit Compliance Compensation (calculate and enable breathing circuit compliance of flow/volume delivery), enable 90-second Slow Inflation, Altitude Compensation, Language Selection, Violation Message Log.
Bias Flow
Ventilator-set bias flow flushes exhaled CO2 and stabilizes temperature, humidity and baseline pressure in the patient breathing circuit.
Non-invasive Ventilation
Compatible with mask ventilation for continuous or short term use.
O2 Calibration
Automatic oxygen sensor calibration at software determined intervals.
Preset Vent Settings
Mode, Breath type and settings can be preset without affecting current ventilator operation.
01.04.02.02 Non invasive ventilation, devices for
01.04.02.03 Emergency and transport respiration equipment