Company Profile

About us
Micro-Tech (Nanjing) Co., Ltd is a joint venture, located in Bio-Medicine Park of National High-Tech Development Zone. As a member participating in “One hundred projects within ten years” hosted by Ministry of Health P.R. of China, Micro-Tech specializes in developing, manufacturing and distributing of stents series products, biopsy forceps and other medical devices for minimal invasive operation. Micro-Tech has got tens of patents for its products. The representative offices of Micro-Tech distribute over the country to serve our customers in the shortest time. We can offer special designed products to satisfy your individual requirements in clinical application within ten to twelve hours.

Housing more than 1500 squire meters of Ten Thousand GMP workshops, including some Hundred GMP workshops, Micro-Tech has been the only one domestic manufacturer with that standard.

Having collaborated with clinical professionals, our products developing ability has been substantially improved. Micro-Tech provide customers with safe, convenient, effective and innovative products.

Patented cup-mouth ended esophageal stents considerably reduce the trauma from stents implanting .Machine-braid stents, comparing to traditional hand-made stents are more flexibility and decreased the possibility of punching.

Gastrooesophageal connecting stents successfully solve the problems left before and could be taken out within three to fours weeks after the operation.
Package sterilized by ethylene oxide (EO), stents prevent the possible infection during operation. The relocation function of our stents permits the physicians to adjust the positions of stents when deploying them and the safe-lock structure highly improve the precision in performing .

The material of MTN-HT single-use endoscope biopsy forceps has been proved biocompatible. In the operation procedure of the forceps, the flexible outward sheath of forceps eases insertion and complys the tortuous ducts in human body. The forceps can be inserted into stomach and duodenum with endoscopes. In order to eliminate cross-infection caused by reuse, the handle of biopsy has installed self-locking parts. The maximum trial operation should be no more than eight.

And one of our products being developed is biodegradable stent, expected to be applied in benign duct-narrowed patients. This kind of stent can degrade after dilating the stenosising ducts without second operation to be take out. Endo-radioactive stent dilates narrowed ducts thoroughly with radioactive agent, particle I125.

Micro-Tech will keep collaborating with experts in clinical field to improve product quality in the future. Step forward everyday is our creed. We encourage you to join in the spirit of our adventure and continue your exploration of our web site.

Product Information
05.06 Disposable articles for hospitals
3-FREE woven esophageal stent system 26.10.2007

Bounded introducers, proximal accurate and easy positioning. Unique lengthways clearanle, compliable and retraltable design. No bending stress, compliable with the intestines, less contradictions. When transversely compressed, no changes in lengthways forces and dimensions, less stimulate and replacement. Possible to be discharged by specific mechanism. The cup-mouth-spherial shape end together with silicone edge design decreases hyperplasia.

Coated woven radioactive stent 26.10.2007

Radioactive stent’s application is made up of the stent together with introducer, radio-isotopes. Have a CT examination, then build a Three-dimensional image. Presicribed by the doctor according to CT shadow. According to the prescription, pierce the puncture needle about 18G into the stents filling tube on the corresponding perimeter and height of the stent and the focus. Insert the stent in the same way as common bounded stent’s system(Refer to the detailed introduction).

Disposable Urethra Stent Introducer (for Vesico Set) 26.10.2007

DIRECTIONS FOR USE 1. Selecting the length of the stent: The stent should be 15 mm longer than the stenosis segment. After it has been settled down, the distal extremity of the stent should be 5 mm lower than the stenosis segment and the proximal extremity should be about 10 mm higher. 2. Selecting the diameter of the stent: Select stents of various diameters according to the patient’s conditions. Select the 12mm stent for the patients in a general way. 3. The operating procedure: Sterilize routinely the 0 type cystoscope, stent, optical fiber and the introducer. Take the local anesthesia or epidural anesthesia to the patient and use the cystoscope to observe the situation of the stenosis. Then select a suitable stent according to the length of the stenotic urethral tract nearby the prostate measured through the cystoscope. Withdraw the cystoscope and insert it into the inner ostium of the introducer which contains the stent. Then insert the introducer into the urethral tract together with the cystoscope and stent. Settle the stent openly on the condition that the proximal end of the stent doesn’t stick out into the bladder and the distal end is not lower than the seminal vesicle. Observe the position of the stent after settling it and can adjust its location with biopsy forceps.

Four-rod Connecting Structure 26.10.2007

Under the surveillance of endoscope, biopsy forceps can insert into the alimentary tract and clamp the mucous membrane tissue. It has the chances of contiguity with the blood, and been used repeatedly, so if not been strictly sterilized, there would be the potential possibility for cross infection and increase the chances of infected by contagious diseases, such as Hepatitis B and HIV. Therefore, laws and statutes have established that disposable biopsy forceps must be used when operating the experiment of gastroscopy in USA, Canada and France. In Europe and Japan, disposable biopsy forceps has been generally accepted by the doctors and the patients, and is a popular trend for biopsy forceps.
?Rigid connective qua-pole structure
?The jaw and the spring coil are welded by laser
?Maximum tensile strength can reach 10Kg
?The distal clamp part can pass through tract bended of 210 degree
?Elliptical stainless jaws with the length of 2.3mm have lateral holes
?Clear starting and ending point accord with the customs of the doctors
?Sterile package, can be used for instant open

Four-rod Connecting Structure with spike 26.10.2007

Under the surveillance of endoscope, biopsy forceps can insert into the alimentary tract and clamp the mucous membrane tissue. It has the chances of contiguity with the blood, and been used repeatedly, so if not been strictly sterilized, there would be the potential possibility for cross infection and increase the chances of infected by contagious diseases, such as Hepatitis B and HIV. Therefore, laws and statutes have established that disposable biopsy forceps must be used when operating the experiment of gastroscopy in USA, Canada and France. In Europe and Japan, disposable biopsy forceps has been generally accepted by the doctors and the patients, and is a popular trend for biopsy forceps.
?Rigid connective qua-pole structure
?The jaw and the spring coil are welded by laser
?Maximum tensile strength can reach 10Kg
?The distal clamp part can pass through tract bended of 210 degree
?Elliptical stainless jaws with the length of 2.3mm have lateral holes
?Clear starting and ending point accord with the customs of the doctors

Straub-Rotarex-System 26.10.2007

The Straub-Rotarex-System was developed for mechanical thrombectomy and is used for the removal of fresh and organized thrombi from arteries and peripheral veins. It is the most effective and safest thrombectomy medical device so far. The researches in many oversea institutions prove positively of the effectiveness of Straub-Rotarex-System, while domestic research also indicates the promising application of Straub-Rotarex-System.

Twin wire Structure 26.10.2007

Under the surveillance of endoscope, biopsy forceps can insert into the alimentary tract and clamp the mucous membrane tissue. It has the chances of contiguity with the blood, and been used repeatedly, so if not been strictly sterilized, there would be the potential possibility for cross infection and increase the chances of infected by contagious diseases, such as Hepatitis B and HIV. Therefore, laws and statutes have established that disposable biopsy forceps must be used when operating the experiment of gastroscopy in USA, Canada and France. In Europe and Japan, disposable biopsy forceps has been generally accepted by the doctors and the patients, and is a popular trend for biopsy forceps.
?Rigid connective qua-pole structure
?The jaw and the spring coil are welded by laser
?Maximum tensile strength can reach 10Kg
?The distal clamp part can pass through tract bended of 210 degree
?Elliptical stainless jaws with the length of 2.3mm have lateral holes
?Clear starting and ending point accord with the customs of the doctors

Twin wire Structure with spike 26.10.2007

Under the surveillance of endoscope, biopsy forceps can insert into the alimentary tract and clamp the mucous membrane tissue. It has the chances of contiguity with the blood, and been used repeatedly, so if not been strictly sterilized, there would be the potential possibility for cross infection and increase the chances of infected by contagious diseases, such as Hepatitis B and HIV. Therefore, laws and statutes have established that disposable biopsy forceps must be used when operating the experiment of gastroscopy in USA, Canada and France. In Europe and Japan, disposable biopsy forceps has been generally accepted by the doctors and the patients, and is a popular trend for biopsy forceps.
?Rigid connective qua-pole structure
?The jaw and the spring coil are welded by laser
?Maximum tensile strength can reach 10Kg
?The distal clamp part can pass through tract bended of 210 degree
?Elliptical stainless jaws with the length of 2.3mm have lateral holes
?Clear starting and ending point accord with the customs of the doctors
?Sterile package, can be used for instant open
?Conventional and stable structure

Uncoated woven radioactive stent 26.10.2007

Radioactive stent’s application is made up of the stent together with introducer, radio-isotopes. Have a CT examination, then build a Three-dimensional image. Presicribed by the doctor according to CT shadow. According to the prescription, pierce the puncture needle about 18G into the stents filling tube on the corresponding perimeter and height of the stent and the focus. Insert the stent in the same way as common bounded stent’s system(Refer to the detailed introduction).

Woven radioactive stent together with introducer 26.10.2007

Radioactive stent’s application is made up of the stent together with introducer, radio-isotopes. Have a CT examination, then build a Three-dimensional image. Presicribed by the doctor according to CT shadow. According to the prescription, pierce the puncture needle about 18G into the stents filling tube on the corresponding perimeter and height of the stent and the focus. Insert the stent in the same way as common bounded stent’s system(Refer to the detailed introduction).