Company Figures
Number of employees 500-999
Export content max. 50%
Year of foundation 1992
Area of business

Company Profile

OUR OFFER
• implants - plates, nails, bone screws, DHS plates etc.
• surgical instruments (scissors, tweezers, forceps etc.)
• dental instruments for surgeries or rotary instruments
• production according to customers´ documentation and requirements

Product Information
01.03.03 Implants and protheses
Joint thumb endoprosthesis CMC 11.10.2007

Endoprosthesis is an integral casting consisting of cylindrical body and a square anchoring pin. Cylindrical body is ended with top articulatory concavity that makes the contact surface for the navicular bone after operation. On the opposite side of the endoprothesis cylindrical body is the anchoring pin of square cross-section ended with a truncated pyramid which enables fixation of the endoprothesis in the cavity of the first metacarp.

MEDIN Cylindrical MC-T, MC-S 11.10.2007

The stem is used as a part of the total hip joint replacement as a solution of late degenerative and inflammatory illnesses and some injury states. We recommend to use it with hip heads and acetabular replacements MEDIN.

MEDIN Modular - MM 11.10.2007

The implant is determined for primary knee joint replacement that is fixed by cement. It is particularly used for osteoarthritis, also kneejoint destructions arising from inflammatory rheumatic illnesses and other systemic illnesses. The implant can also be a solution for some knee injuries and posttraumatic states.

MEDIN OVAL MODULAR - MOM 11.10.2007

Oval acetabulum is mainly indicated for larger cavity and segment defects of a bone bed. Oval socket shape enables optimal preservation of bone tissue and motion of contact spherical surface to original position when using eccentric insert.

MEDIN Oval - MO 11.10.2007

Oval acetabulum is mainly indicated for larger cavity and segment defects of a bone bed. Oval socket shape enables optimal preservation of bone tissue and motion of contact spherical surface to original positron when using eccentric insert.

MEDIN Spherical - MS, MEDIN Spherical Optimal - MSO 11.10.2007

The implant is part of primary hip joint replacement system applied without bone cement. It is also indicated for serious arthropathy arising from rheumatic arthritis or osteoarthritis when conservative treatment is no more effective. The same indication is also valid for difficult posttraumatic states and some systemic illnesses.

MEDIN Universal - MU 11.10.2007

The implant is determined for primary knee joint replacement that is fixed by cement. It is particularly used for osteoarthritis, also kneejoint destructions arising from inflammatory rheumatic illnesses and other systemic illnesses. The implant can also be a solution for some knee injuries and posttraumatic states.

MEDIN Wrist Replacement 11.10.2007

The implant is used for primary replacement of wrist joint especially in case of osteo-arthrosis and destruction of the wrist joint arising from inflammatory rheumatic diseases and other systematic illnesses. The implant can be used even to treat some injuries of the wrist and for solutions of after-traumatic consequences.

MEDIN ball heads 11.10.2007

The basic shape of the hip ball head is spherical. For an extra long design the ball head is elongated by means of a cylindrical part to guarantee minimal length of the spherical surface. A self-locking cone is used to fix the ball head to the femoral component.

MEDIN tendon temporal replacement 11.10.2007

The implant is determined for tendon temporal replacement of hand flexor. Tendon temporal replacement silicone has a cylindrical shape with a smooth surface. The replacements are supplied in diameters 3, 4, 5, and 6mm, in lengths 120 and 180 mm, on special request 220 mm.