Bio Medical Technologies Co., Ltd

Megu Bldg., 431-17 Shindang 2-dong
100-452 Seoul
Korea (Rep.)

Phone: (+82-2)22340780
Fax: (+82-2)22340748
http://www.bm-tech.co.kr
bmtshin@kornet.net

Company Contacts
Department/ Name Address

Overseas Sales Dept Megu Bldg., 431-17, Shindang 2-dong, Jung-gu, Seoul, Korea, T.822 2234 0780, F.822 2234 0748
bmtshin@kornet.net

Company Figures
Number of employees 1-19
Sales volume 1-9 Mio US $
Export content max. 75%
Year of foundation 2000
Area of business Electronical Equipment / Medical Technology

Diagnostics

Language: German Language: English Company Profile

Company Introduction & Business Category
We, BMT(Bio Medical Technologies Co., Ltd)are Korean manufacturer producing Spo2 disposable/reusable pulse oximetry sensors and cables used for non-invasive measurement of blood oxygen saturation and pulse rate measurement. BMT Spo2 sensors are able to apply finger position and connected with whole fields of pulse oximeter and patient monitoring system.
BMT Spo2 oximetry sensors are compatible with major patient monitor or pulse oximeters. We would like to supply our qualified products to you on favorable terms. We are able to supply Spo2 adapter, extension cable, complete sensors. If you need more detailed information of BMT sensors, Please, feel free to contact us or visit our web site www.bm-tech.co.kr

Product Information
01.03.09 Lithotripsy equipment
1. BM-100 24.10.2007

o Application : Adult
– Preferred application site is index finger
– Alternative sites are thumb, smaller finger and big or second toe
o Usage : Disposable
o Shape : Adhesive Type
o SpO2 Accuracy : 70~100% ±2 digit
o LED Specification
– Red & Infrared, nominal
o Photodiode Specification
– Active Area : 5mm2
– Responsibility : 0.18Min (0.21 typical) @436nm

2. BM-200 24.10.2007

o Application : Adult/Neonatal
– Preferred application sites are index finger and foot below the toes with the cable running along sole of foot
– Alternative sites are palm of hand and other fingers
o Usage : Disposable
o Shape : Adhesive Type
o SpO2 Accuracy : 70~100% ±2 digit
o LED Specification
– Red & Infrared, nominal
o Photodiode Specification
– Active Area : 5mm2
– Responsibility : 0.18Min (0.21 typical) @436nm

5. BM-500 24.10.2007

o Application : Infant
– Preferred application site is a toe with cable running along sole of foot
o Usage : Disposable
o Shape : Adhesive Type
o SpO2 Accuracy : 70~100% ±2 digit
o LED Specification
– Red & Infrared, nominal
o Photodiode Specification
– Active Area : 5mm2
– Responsibility : 0.18Min (0.21 typical) @436nm

01.04.04 Patient monitoring systems / Measuring stations

01.04.04.06 MR Patient moniting

01.04.04.08 Oximeters, oxygen saturation meters

01.04.04.09 Patient monitors